Call us free on 0800 052 3455
Products  Categories
Mitsubishi Aircon / Heat Pumps Mitsubishi Aircon / Heat Pumps
Mitsi Elec Aircon / Heat Pumps Mitsi Elec Aircon / Heat Pumps
LG Aircon / Heat Pumps LG Aircon / Heat Pumps
Fujitsu Aircon / Heat Pumps Fujitsu Aircon / Heat Pumps
Daikin Aircon / Heat Pumps Daikin Aircon / Heat Pumps
Hitachi Aircon / Heat Pumps Hitachi Aircon / Heat Pumps
Panasonic Aircon / Heat Pumps Panasonic Aircon / Heat Pumps
Samsung Aircon / Heat Pumps Samsung Aircon / Heat Pumps
Air To Water Heat Pumps Air To Water Heat Pumps
Aircon No Outdoor Unit Aircon No Outdoor Unit
Portable Air Conditioning Portable Air Conditioning
Swimming Pool Heat Pumps Swimming Pool Heat Pumps
Dehumidifiers All Types Dehumidifiers All Types
Heaters - All Types Heaters - All Types
Cast Iron Stoves - Wood Burners Cast Iron Stoves - Wood Burners
Fitting Kits Fitting Kits
Accessories Accessories
Shipping Of Systems to Europe Shipping Of Systems to Europe
Terms & Conditions Terms & Conditions
Full Products List Full Products List
We accept
European Customers
British Pound Euro
Customers can have up to 4 systems delivered to a European destination for a delivery charge of 175 €. This delivery charge will need to be ‘added to the cart’, and details can be found at the end of each product category page
 
 
Heat Pumps Some Key Facts

Air To Water Heat Pumps and Air to Air Heat Pumps use exactly the same principle which as I can hear you all asking what’s that then? Well to put it into a simple phrase you can summarise this by saying “The manipulation of the properties of refrigerant gas”. Now there are loads of good places on the web where you can get in depth technical descriptions of this process so we will just give a brief description and concentrate on the practical aspects of this technology, and how it relates to domestic and commercial applications.

If you remember from your school days that apart from absolute zero which is -273*centigrade or there about’s their will always be heat in the air. Consider when you’ve sat on a stone wall and it feels cold (well there you go that’s basically the principle of heat pumps, your bum is warmer than the wall hence warmth is transferred from you to the wall). So from the above if we have a refrigerant that is colder than the surrounding air, heat will be absorbed into the refrigerant. We can use this heat absorbed into the refrigerant and transfer this heat to an indoor unit. The heat is then given up at the indoor unit to provide generally space heating or via a heat exchanger to heat water, this water can then be used in an under floor heating circuit for instance and also to provide domestic hot water.

Let’s talk about Air to Air Heat Pumps first – In this type of system you’re using the heated refrigerant going to the indoor unit and passing air over the heated coils to provide heat to a room. This type of technology has been around for a long time but the usage of this technology in Britain is a fairly recent event. Us Brits like to use what we know so hence gas central heating has been probably the most common type of heating over the last three decades. There still tends to be a lot of misconceptions with regard these systems and what they can actually do, so let’s give a few concrete facts to help you decide if this type of technology is for you.

How Energy Efficient Are These Systems?  - Well very, but a bit like fuel performance figures for cars you tend to be given the best optimum conditions with the truth somewhere in the middle. You can get energy efficiency ratings of up to a COP value of 6 and on these systems. The COP (Coefficient of Performance) value is telling you how much useful heat energy you’re getting out for every £1 pound of electrical energy you’re putting in. Hence a COP value of 5 means you will get £5 pounds of heat energy out for the £1 pound of electrical energy you’ve put in, which as I’m sure you will agree sounds very impressive. So basically the bigger the COP number the more energy efficient the system is, as a good guideline any system with a COP value of 3.6 and over can be considered to be particularly energy efficient. Here’s the slight but though with these systems and also why Britain has the perfect climate for these types of systems. Remember we said the refrigerants colder than the air hence it’s absorbing heat, so basically this COP figure we keep going on about is telling you how much heat energy is being absorbed in relation to the input energy used, now where in danger here of getting a bit to technical so let’s keep it simple.

Why Are They Suited To Our Climate - Our climate is quite temperate and for most of the population it rarely goes below -10*c, 95% of the time temperatures stays within a range of (25*c) – (-3*c). Now our refrigerant temperature is at around (-27*c) so useful heat transferred into the refrigerant will occur throughout this temperature range but as we get to zero and below less heat will be absorbed into the refrigerant from the air, hence our COP figure of say 5 drops. The system will still work and give the required heat output down to outside air temperatures of (-15*c) but this COP value will decrease the colder you get. Now the reason we said these systems are well suited for the our British climate is the fact that for around 90% of the time you will get the COP values indicated by manufacturers, but when it does get cold and go below zero the energy efficiency will drop. You can see below the COP graph of our best selling Mitsubishi Ultra Efficiency systems and see how the outside air temperature effects the performance of the system.

An air source heat pump has three different cycles which are the heating cycle, the cooling cycle and the defrost cycle.

The Heating Cycle - During the heating cycle, heat is taken from the outdoor unit and transferred to the indoor unit.

  • First the liquid refrigerant passes through the expansion valve, changing to a low pressure liquid / vapour mixture. It then goes to the outdoor coil, which acts as the evaporator coil. The liquid refrigerant absorbs heat from the outdoor air and boils, becoming a low temperature vapour.
  • This vapour passes through the 3 way reversing valve to the accumulator, which collects any remaining liquid before the vapour enters the compressor. The vapour is the compressed, reducing the volume and causing it to heat up.
  • Finally, the reversing valve sends the gas, which is now hot, to the indoor unit, which is now the condenser. The heat from the hot gas is transferred to the indoor area causing the gas to condense back into a liquid. This liquid is returned to the expansion valve where the cycle is repeated.
  • The ability of an air source heat pump to transfer heat from the outside air to where it is required inside a building depends on the outside air temperature. As the outside air temperature drops, the ability of the heat pump to absorb heat also drops, hence the rated COP value of the system drops.

The Cooling Cycle - The cycle described above is reversed to cool the house during the summer. The unit takes heat out of the indoor air and rejects it to the outside.

  • As in the heating cycle, the liquid refrigerant passes through the expansion device, changing to a low pressure  liquid / vapour mixture . It then goes to the indoor coil, which acts as the evaporator. The liquid refrigerant absorbs heat from the indoor air and boils, becoming a low temperature vapour.
  • The vapour passes through the reversing valve to the accumulator, which collects any remaining liquid, and then to the compressor. The vapour is then compressed, reducing its volume and causing it to heat up.
  • Finally, the gas, which is now hot, passes through the reversing valve to the outdoor coil, which acts as the condenser. The heat from the hot gas is transferred to the outdoor air, causing the refrigerant to condense into a liquid. The liquid returns to the expansion device, and the cycle is repeated.

During the cooling cycle, the air heat pump also dehumidifies the indoor air. Moisture in the air passes over the indoor unit coil condensing on the coil's surface, this water is then collected in the drip pan at the bottom of the indoor unit. The water is then taken away via the condensate drain attached to the indoor unit drip pan.

Defrost Cycle - If the outdoor temperature falls to near or below freezing when the heat pump is operating in heating mode, moisture in the air passing over the outside coil will condense and freeze on it. The amount of frost build up depends on the outdoor temperature and the amount of moisture in the air.

This frost build up will decrease the efficiency of the coil by reducing its ability to transfer heat to the refrigerant. At some point the frost must be removed. To do this, the air heat pump will switch itself into defrost mode. On most split system heat pumps when the system goes into defrost mode the indoor unit stops its heating function and turns the indoor fan off. Defrost mode is then turned on which is cooling mode without the indoor fan on. This sequence will generally last around 10 minutes with the hot air being expelled at the outdoor unit melting any ice and frost build up.

Typically you can expect an air source heat pump operating below an outside air temperature of 0*c in heating mode to go into defrost mode once every 2-3 hours.

 
 